FAQ
How to install the V®500 Connect's outdoor panel?
(3)
2023-12-08 08:20:00.0

We advise you to install the door station at a height of about 1.60 m and to avoid placing the camera opposite a light source, as this may reduce the quality of the images/videos taken of the visitors.
1. Route all the cables in the rain shield, then fasten it to the wall/pillar.
2. On the door station, connect:
- the cable of the indoor monitor to the terminal blocks M+ and M-. The polarity is irrelevant (A)
- the cable from the electric latch of the pedestrian gate to the terminal blocks L+ and L- (B)
- the cable from the gate drive to the dry contact output (COM and NO) (C)

Using the screwdriver, press the square notch, insert the cable then release:

3. Place the door station in the rain shield and screw it in using the assembly key supplied (E).

4. Install the name plate:
- Turn the call button anticlockwise to the engraved marking then remove.
- Remove the round membrane to access the name plate label.
- Write your name on the white label using a permanent marker, then refit the label and its cove in the housing.
- Reassemble the call button on the door station using the marks, and then turn clockwise until it locks.